Aims and Scope

Proficiency Tests (PT) give participants the opportunity to demonstrate technical competence, meet accreditation requirements, and gain confidence by comparing their results with those of other laboratories. They also provide independent insight into measurement performance, strengthen quality systems, and support risk management in line with ISO/IEC 17025:2017.

VSL organizes PTs under ISO/IEC 17043:2010 accreditation with the highest care, offering:

• A suitable traveling standard;
• A clear test protocol;
• An independent assessment report;
• Anonymous comparison of results;
• Optional metrological and quality management support.

Image expert

Questions?

Our experts are at your service.

Jaïr Blom
PT coördinator

Confidentiality statements

VSL keeps all data regarding the performance of individual participants, or groups of participants, strictly confidential. Data is accordingly protected and stored in areas on networks with restricted access. The relationship between results and the laboratories that submitted them will never be disclosed. Only the laboratory is granted access to its performance through the assigned code number.

Payment Terms

Payment in advance, at least one month before the start.

Failure to pay on time may result in exclusion from participation, without any right to refund or compensation.

Criterion of participation

Participation is open to any laboratory performing temperature instrument calibration, whether accredited to ISO/IEC 17025 or seeking accreditation.

Participants

This PT is open to 5-10 participants. If fewer than 5 laboratories register, VSL may cancel or postpone the PT. In such cases, all registered participants will be notified and offered alternative options.

Quantities to be measured

-10, 0, 20, 40, 60, 80, 100 and 120 °C.

Schedule

The PT will start on the date specified on our website.

Instruments will be delivered by courier to each participant. Each laboratory will have three weeks to perform the measurements and submit the results before the instruments will be sent to the next participant. The aim is to release the PT report no later than six weeks after the deadline for submitting the results by the participants. Detailed instructions and contact information will be provided.

Travelling Standard

The instrument used in this PT will be a Dry Block – Fluke 9172 (Metrology Well Calibrator) A65070.

Equipment Choice

Participants are advised to use their routine methods and equipment when performing measurements and calibrations. These should be carried out in accordance with the laboratory’s usual practices.

Instructions and protocol

VSL will provide the protocol before shipping the instruments. Each participant will have at least three weeks to perform the measurements and submit the results. A report sheet will be provided for submitting the results.

Assigned Value

Reference values will be determined by VSL using traceable calibrated standards. These assigned values form the basis for evaluating each participant’s measurement results.

Performance evaluation

The results will be evaluated using the normalized error (En-score).

Interpretation of the En-score is as follows:

|En| <= 1 Satisfactory performance

|En| > 1 Unsatisfactory performance

The final report presents results anonymously. Each laboratory can identify its own performance via a unique code. VSL guarantees full confidentiality and does not share individual data with third parties.

Deliverables

Upon completion of the PT, each participant will receive:

• A detailed report with anonymized results;

• An individual performance evaluation.

This report may serve as supporting evidence for audits and internal reviews.